Braced Wall Specification Changes to the 2009 IRC (pt. 2)

The newest edition of the International Residential Code sees some changes to the requirements of wall bracing. A new requirement (ref. section R602.10.1.2.1) is one that ties the braced wall panel construction prescribed in chapter 6 to the roof-ceiling construction prescribed in chapter 8. Section R602.10.1.2.1 applies to all exterior walls that support roof structure whether it consists of rafters or pre-engineered trusses.

In a nutshell, this section tells us that if the net uplift value at the top of the framed wall due to the roof structure does not exceed 100 pounds per lineal foot (PLF) the framing members of the wall (studs, plates, etc.) should be fastened according to Table R602.3(1), which is the minimum typical fastening allowed by the code. The net uplift value is determined by the provisions of section R802.11.

If the net uplift value exceeds 100 PLF, each individual framing member should be connected so that a continuous load path is created from the top of the wall to the foundation. As an example, Simpson Strong Tie has clips such as the H4 and the H8 (shown below) that provide additional anchorage to the studs to help them meet this requirement.

simpon H4 and simpson H8

Simpson H4 and Simpson H8 clips.

The following detail illustrates fastening that will create a continuous load path from the top of wall to the foundation.

Continuous load path detail

Continuous load path illustration

Related Articles:
  1. Braced Wall Specification Changes to the 2009 IRC (pt. 1)
  2. Reducing Holdowns Using OSB Exterior Sheathing
  3. Wall on Grade Foundation
  4. Staples or Nails? Choosing the Right Fastener for Wall and Roof Sheathing
  5. Three Wood Framing Methods – Balloon, Platform & Advanced
  6. Wall Steel Observation for Hughes Home with Tall Basement Walls and Pool
  7. Jefferson County Code Supplement Deletes 2009 Residential Fire Sprinkling Requirements
  8. Denver Metro Area Jurisdictions Converting to 2009 International Codes

Tagged as: , , , , , ,

Leave a Response


EVstudio Architect Engineer & Planner Online Magazine
Denver & Evergreen Colorado, Copperas Cove Texas
Yes, we take outside article submissions.