Residential Stair Design – Guidelines, Criteria and Dimensions
I received a question about stair width from one of our clients and thought it made sense to clarify the typical stair design rules for houses. These are the rules that are in the 2006 International Residential Code.
Stairways have to be at least 36" clear width above the handrail height. Handrails can't project more than 4.5" into each side.
You need at least 80" of head height throughout the stair.
The maximum height of a riser is 7.75" and the treads have to be at least 10" deep. Treads also need to be a minimum of 4" tall.
If you have winders they can't be shallower than 6" and they have to be at least 10" deep when you're 12" into the winder.
The landings must be at least as deep as the stairs are wide and you can't go up more than 12' without a landing.
Handrails have to be mounted between 34" and 38" above the tread nosing and must run the full length of the stairs. The handrails have to be at least 1.5" off the wall and where they are circular they need to be 1.25" to 2" in diameter. If the handrail isn't circular it needs to have a perimeter between 4" and 6.25" with a maximum cross section of 2.25".
There are a number of other rules for particular situations but these are the general guidelines. There are more difficult stair and handrail rules for commercial and multifamily dwellings. I've also written a separate post for spiral stairs.
Originally posted 2008-09-29 17:01:01.
Related Articles:- Commercial Stair Design – Guidelines, Criteria and Dimensions
- Commercial Ramp Design – Guidelines, Criteria and Dimensions
- Residential Spiral Stairs – Guidelines, Criteria and Dimensions
- Handrail Extensions for Commercial Stairs
- New Definitions of Stair and Stairway Under 2009 IRC
- Stair Construction Tolerance and Dimensional Uniformity
- Residential Stairs Type in the 2009 IRC
- Ramps that Don’t Require Handrails, Slope and Rise
6 Responses »
Trackbacks
- Commercial Stair Design - Guidelines, Criteria and Dimensions « EVstudio Architecture, Planning & Design Blog | Denver & Evergreen Colorado Architect
- Residential Spiral Stairs - Guidelines, Criteria and Dimensions « EVstudio Architecture, Planning & Design Blog | Denver & Evergreen Colorado Architect
Leave a Response
Entries(RSS)
EV Studio
is there a code for exterior residential concrete stairs as far as the slope of the tread?
my contractor pitched each stair tread 3/4" each
it feels hard to walk down as your weight leans towards the ball of foot as you walk down
seems excessive to me
is there a min and maxium per boca code i should know before going to city to discuss?
the contractor sdays that it normal of 3/4 inch
trace
Assuming this is the international residential building code your contractor is 100% wrong. It states "The walking surface of treads and landings of stairways shall be sloped no steeper than one unit vertical in 48 inches horizontal." In a 12" deep tread that's 1/4" of outslope.
I would advise you to rectify that immediately, in rain and certainly in ice that amount of outslope is very dangerous.
In a residential situation, can the landing be a hallway? That is, can the stairway end like a room door into a hall way as long as the hallway is as wide as the stairs?
thanks
The clear space at the top or bottom of residential stairs can be part of a hallway.